Dynamic Load Balancing

A function that continuously measures the building's consumption and automatically lowers the charging power so the supply limit is not exceeded.

Technical level:Intermediate

A meter or current sensor is installed at the incoming supply in the main panel and tells the charger how much current the house is drawing. When the water heater, cooker and air conditioners run together, the charger turns down; when those loads switch off, it ramps up again. Where there are several chargers, the same logic shares the available power among them.

This often avoids upgrading the supply and tripping the main breaker, a common problem in homes with a single-phase supply.

AC charging cannot run below 6 A per phase; if the margin falls lower, charging pauses temporarily. Install the sensor upstream of all the building's loads, not on a single circuit.