How to choose a rack cabinet in seven steps
Tips for choosing a rack: type, height in U, depth and width, weight limit, ventilation, doors and locks, accessories, and UPS.
Short answer: to choose a rack, first decide on wall-mounted or floor-standing, calculate height in U with a 30% margin, choose enough depth for your deepest device, check the weight limit and ventilation, and add the accessories you need.
Key factors
To choose the rack that will protect your equipment properly and cost-effectively and organize your network cabling in the best possible way, consider the following factors:
- Wall Mount
- Freestanding
- Open Frame Cabinets
- Enclosures
Dimensions
(Dimensions explained)
- Height
- Depth
- Width
Special features
See them in detail here.
Seven steps to choosing a rack
- Type: wall-mounted for a small amount of equipment (networking, cameras), floor-standing for servers, UPS systems, and many switches. See rack types.
- Height in U: add up the equipment's U and add approximately 30%. See the worked example.
- Depth and width: enough depth for the deepest device plus rear cable space; 800 mm width for dense cabling.
- Weight: add up equipment weight, especially UPS systems and batteries, and compare it with the cabinet's limit (from 80 kg for small wall-mounted cabinets to 1,000 kg for DYNAMAX).
- Ventilation and doors: perforated doors and fans for servers and UPS systems, a glass door for visual inspection, and locks in shared areas.
- Accessories: rack power distribution units (PDU), shelves, vertical cable managers, patch panels, blanking panels, casters.
- UPS for the cabinet: a rack UPS typically occupies 2U. See rack or tower UPS.
Quick guide by location
| Location | Recommendation | Lande series |
|---|---|---|
| Home or small office (router, switch, NVR) | Wall-mounted 6–12U | WB PROlineB, PROlineB |
| Store or office with NAS and UPS | Wall-mounted 12–20U or small floor-standing | PROlineB, DYNAMIC BASIC |
| Server room | Floor-standing 42U, 1,000 mm deep | DYNAMAX, HYPERLINE |
| Dusty or damp location | Sealed IP55 | SAFEBOX B |
| Outdoor location | Sealed outdoor IP55 | SAFEBOX B Outdoor |
Frequently asked questions
What rack do I need for a small office?
Usually a 9–12U wall-mounted cabinet, with room for a router, switch, patch panel, recorder, and small UPS.
How many U should I choose?
As many as you need today, plus approximately 30% for future additions and proper airflow.
Wall-mounted or floor-standing rack?
Wall-mounted for light networking equipment. Floor-standing when you have servers, UPS systems with batteries, or many switches, because of weight and depth.
Want us to recommend the right cabinet? Contact Tescom Hellas.