Expanding UPS batteries: how it works
How to extend UPS runtime: external batteries, XL models with a higher-capacity charger, charging time, and why a bigger battery alone is not enough.
Short answer: for more runtime, you need a UPS designed for external batteries (XL or long-run models), with a higher-capacity charger capable of charging them. Connecting a larger external battery to a standard small UPS is not the right solution.
Why the charger sets the limit
UPS systems are usually designed with chargers that support a specific number of batteries, and therefore a specific runtime they can provide.
Some UPS systems have an enhanced charger that can multiply the number of batteries it can charge, which in turn increases the runtime.
XL models and external battery packs
XL (or long-run) models come without internal batteries or with only a few, and connect to external battery packs or cabinets. For example, the PRIME PLUS series has a higher-capacity charger of up to 8 A in its 1–3 kVA models, allowing it to charge significantly greater battery capacity.
How long recharging takes
A rough calculation for lead-acid batteries:
Recharge time (hours) ≈ battery capacity (Ah) ÷ charger current (A) × 1.2
Example: 100 Ah batteries with an 8 A charger: 100 ÷ 8 × 1.2 ≈ 15 hours for a full recharge. If outages are frequent in your area, consider recharge time alongside runtime: a second outage before the batteries are charged gives you less time.
Why not connect a large battery to a small UPS?
- A small UPS charger is designed for a low Ah capacity: a large battery would take days to charge and remain chronically undercharged.
- A small UPS inverter and cooling system are not designed for hours of battery operation.
- The cables and fuses are not sized for this use.
Other ways to get more runtime
- Lithium UPS: more runtime in the same size, such as LiON, with up to 26 minutes at 50% load.
- Lower load: connect only critical equipment to battery-backed outlets. See how long a UPS runs.
- UPS and generator: for extended outages, the UPS bridges the gap until the generator takes over.
For more information about UPS systems whose runtime can be extended, you can contact the Tescom Hellas experts and they will be glad to help.
Frequently asked questions
Can I connect an external battery to my UPS?
Only if the UPS has an external battery connector and a charger designed for external batteries, as XL models do. Check the specifications or ask us.
How long does a UPS take to charge?
Small UPS systems with internal batteries usually charge in a few hours. With external batteries, divide Ah by charger current and multiply by approximately 1.2.
Want a runtime and battery calculation for your installation? Contact Tescom Hellas.